Texas well grid 10-47
A 7.5-minute quadrangle of the Texas state well grid, mostly in Lamb County and Castro County. 237 reports, median depth 344 ft.
237Reports
344 ftMedian depth
267 ftWater at
18 gpmMedian yield
What you will drill through in grid 10-47
| Depth, ft | What was logged there |
|---|---|
| 0–25 ft | Top Soil 97, Topsoil 82, Caliche And Clay 62, Caliche 59, Sandy Clay 23, Sand-Clay 16 |
| 25–50 ft | Sandstone 20, Sand, Sandstone 12, Fine Sand, Sandstone 10, Sandstone, Sand 9, Sand & Sandstone 6, Sand 5 |
| 50–100 ft | Brown Clay, Sandstone 16, Sand 14, Fine Sand, Sandstone 12, Hard Sandstone, Rock 9, Sandstone 8, Sandy Clay, Sand, Sandstone 7 |
| 100–200 ft | Sandy Clay, Sand, Sandstone 26, Sandstone 20, Fine Sand, Sandstone 22, Sandstone, Sand 20, Sand 17, Brown Clay, Sandstone 16 |
| 200–300 ft | Sand 41, Coarse Sand, Grvl 20, Coarse Sand, Gravel 13, Coarse Sand, Gravel, Clay, Sandstone 7, Sand And Gravel 9, Sand & Gravel 11 |
| 300–500 ft | Red Bed 101, Red And Blue 38, Red Clay 25, Red And Blue Clay 17, Sand & Gravel 15, Coarse Sand, Grvl 16 |
| 500–1000 ft | Red And Blue 2, Blue And Sand Tight 1, Blue And Tight Sndstone 1, Blue And Hard Sndstn, Rock 1, Red And Blue, Sndstn Strks, Snd Strks 1, Hard Sandrock 1 |
Who drills here
| Firm of record | Wells | Median depth, ft | Median yield, gpm | Years |
|---|---|---|---|---|
| HI PLAINS DRILLING, INC. | 73 | 342 | — | 2001–2018 |
| DRILL PRO WATER WELL DRILLING | 27 | 344 | — | 2015–2024 |
| Drill Pro Waterwell Drilling | 18 | 345 | — | 2014–2015 |
| Rodgers Well Service | 15 | 340 | 18 | 2010–2025 |
| PETER KLASSEN | 13 | 344 | — | 2014–2025 |
| N. Blake Scott | 13 | — | — | 2013 |
| Thunder Well Service, LLC | 9 | 393 | — | 2015–2022 |
| B & R IRRIGATION | 8 | 344 | — | 2008–2012 |
| Jeter Drilling Co. | 7 | 338 | — | 2011–2012 |
| Peter B Loewen | 6 | 348 | — | 2021–2024 |
| Ricky Baccus | 6 | 356 | — | 2006–2013 |
| 4 Way Pump Service, Inc. | 6 | 337 | — | 2002–2013 |
| Wilson Drilling, Inc. | 5 | 342 | — | 2005–2018 |
| Baccus Drilling Co. | 5 | 367 | — | 2003–2017 |
| Jacob P Klassen Drilling Co | 5 | 318 | — | 2013–2014 |
| Goyne Drilling | 4 | 345 | 18 | 2007–2008 |
| HOWARD & SONS INC | 3 | 347 | — | 2014 |
| Hydro Resources Mid Continent Inc. | 3 | 640 | — | 2011 |
| Vanguard Well Resources, LLC | 2 | 348 | — | 2018 |
| SANDY LAND DRILLING | 2 | 345 | — | 2011 |
| Jack Spears Drilling | 2 | 334 | — | 2011 |
| VANGUARD WATER WELLS | 1 | 315 | — | 2017 |
| H & F Waterwell Drilling Co. | 1 | 330 | — | 2012 |
| Coy V. Goyne/Goyne Drilling | 1 | 317 | 24 | 2006 |
| Les Taylor Drilling Company | 1 | — | — | 2004 |
What the wells are for
| Purpose | Wells | Share | Median depth, ft |
|---|---|---|---|
| Irrigation | 200 | 84.4% | 344 |
| Domestic | 19 | 8.0% | 345 |
| Stock | 14 | 5.9% | 335 |
| Test Well | 4 | 1.7% | 1,000 |
| Decade | Reports | Median depth, ft | Water at, ft |
|---|---|---|---|
| 2000s | 38 | 342 | 260 |
| 2010s | 154 | 344 | 280 |
| 2020s | 45 | 345 | 275 |
The deepest reports on file
| Report | Year | Depth, ft | Water at, ft | Yield, gpm | Purpose |
|---|---|---|---|---|---|
| 387182 | 2015 | 1,000 | — | — | Test Well |
| 387178 | 2015 | 1,000 | — | — | Test Well |
| 271212 | 2011 | 680 | — | — | Test Well |
| 271207 | 2011 | 640 | — | — | Test Well |
| 43820 | 2004 | 435 | — | — | Irrigation |
| 361174 | 2014 | 434 | 360 | — | Irrigation |
| 622533 | 2022 | 428 | — | — | Irrigation |
| 507354 | 2019 | 428 | — | — | Irrigation |
| 625625 | 2022 | 419 | — | — | Irrigation |
| 643368 | 2023 | 418 | — | — | Irrigation |
Every figure here comes from a report a licensed driller filed on the day the work ended — sometimes decades ago. It describes what was found then, not what a well yields today, and it is not a statement that any well is sound, potable or still in use.
Drilling a well near grid 10-47?
Depth is only half the quote. What it costs depends on the rock, the casing and the pump. Tell us where and we pass the request to licensed Texas drillers.
We are nobody's agent and have no arrangement with any firm today. What we do with this.
This grid falls in Lamb County, Castro County.